Combination Emergency Safety Shower with Eyewash WG7053FY
● Application: Provide full-body relief from contamination fastly and effectively
● Materials: AES plastic + 304 Stainless Steel
Product Features:
1, AES plastic has weather resistance properties and applys to indoors or outdoors;
2, With good acid proof ,alkali prevention performence, 304 SS is ideal for harsh environment;
3, Pull rod with triangular handle is easy to operate for showers;
4, The design with equal length of main pipes makes packaging more compact so that helps to save space and cost;
5, Equiped with flat washer in quick coupling to prevent leakage between joints and fitting;
6, Flow regulator is built in shower arm tube;
7, The shower head delivers a large volume flushing fluid spread evenly in a precise pattern and controlled flow rate;
8, Be activated by push handle or foot pedal easily;
9, The coin slot hidden faucet aerator is easy to remove and clean;
10, Dust cover is removed once unit started;
11, Comply with ANSI Z358.1-2014 and AS 4775-2007.
12, The HS CODE is 8424899990
QUICK COMPLIANCE GUIDE
Combination Unit
1. Valve mechanism activates in one second or less; It stays open until manually closed.(Section 4.2,5.2,6.1.4,6,2)
2. Be connected to a system capable supplying adequate flushing fluid when all components are oprated simultaneously,(Section 4.5.5,7.4.4)
3. Height of the flushing fluid column pattem shall be between 82"(208.3cm) and 96"(243.8cm) above floor. (Section 4.1.3,4.5.4)
4. Watersupply shall be sufficient to supply at least 20GPM (75.7LPM) for 15 mimutes. (section 4.1.2,4.5.5)
5. Valve actuator shall be located not more than 175.3cm (69") above floor. (section 4.2)
6. The diameter shall be minimum of 50.8cm (20") at 152.4cm (60") above floor. (section 4.1.4)
7. Center of the flushing fluid patterm shall be at least 16"(40.6cm) from any obstruction.(Section4.1.4,4.5.4)
8. Water flow pattren shall be positioned between 33"(83.8cm) and 53"(134.6cm) from the level on which user stands and 6"(15.3cm) minimum from the wall or nearest obstruction.(Section 5.4.4,6.4.4)
9. Deliverd at least 3.0 gallons(11.4liters) of water per minute for 15-minute (Section 6.1.6,6.4.5)
10. Construted of materials that will not corrode in the presence of the flushing fluid (Section 7.1.1,7.1.2,7.1.3)
11. Located 10 seconds or 55 feet from contaminants or hazardous materials, Locate on the same level as hazad and free of obstructions.(Section 7.4.2,B5)
12. Protect nozzle head from airborne contamination, dust covers shall be removed by water flow immedlately (Section 5.1.3,6.1.3)
13. Provided fushing fluid to both eye and face simultaneously at a velocity low enough without injury to skin (Section 5.1.1.6.1.1)